WITHIN THE SEALED UNIT
Between the panes
Fog or droplets inside the glass unit may indicate a failed seal. Have the cause confirmed and the possibility of replacing the sealed unit assessed.
A sign to have assessed.
What would you like to explore?
No result matches. You can explore the products or start your project brief.
A CLOSER LOOK AT THE GLASS
A cloudy view between the panes? FenXtra offers insulated glass replacement. The frame can sometimes stay in place, after the opening has been assessed.
Prepare my requestUnderstand the scopeGatineau · Outaouais · Ottawa | Insulated glass · Sealed unit
INSIDE THE GLASS UNIT
On site · Aylmer, Gatineau
Every project starts with an assessment of the glass and its frame. Here is a look at a project while work is underway.

01 / OBSERVE
The location of the moisture matters. These three situations call for different assessments.
WITHIN THE SEALED UNIT
Fog or droplets inside the glass unit may indicate a failed seal. Have the cause confirmed and the possibility of replacing the sealed unit assessed.
A sign to have assessed.ON THE INTERIOR SURFACE
Humid indoor air can condense on cold glass. Humidity and air circulation need consideration; this sign alone does not establish a faulty sealed unit.
Identify the surface before concluding.ON THE EXTERIOR SURFACE
Dew can form outside depending on glass temperature and weather conditions. This alone does not establish a failure of the insulated glass unit.
Also note the time of day.Also mention cracks, water entering the opening or difficulty opening the window. These observations may involve other window components.
Condensation references02 / DEFINE THE RIGHT SCOPE
A sealed unit combines glass panes and a sealed space, held together with a spacer and seals. It is one component of a window, rather than the entire window.
New glass alone does not solve a frame, drainage or operating problem. The scope is confirmed after assessment.
OUR INSULATED GLASS SUPPLIER
FenXtra works with Thermos Rive-Nord for insulated glass units. Replacement glazing is specified after checking dimensions, glass composition and the condition of the existing opening.
Warranty terms are to be confirmed for the selected product.
View warranty information03 / TAKE THE NEXT STEP
These discussion points help connect what you have noticed to a proposal that fits the opening.
Identify the affected openings, rooms and the conditions in which the change appears.
Have the glass, frame, seals and drainage examined. Dimensions and compatibility need to be verified on site.
Have the proposed glass, retained components and included work specified for each opening.
A photo can help locate the opening. It does not replace an on-site assessment or measurements.
The service appears on FenXtra’s public website. The glass and condensation information draws on the references below. Preparation questions are discussion prompts.
Sources checked .
YOUR INSULATED GLASS PROJECT
Prepare an insulated glass replacement request. The assessment will help determine what can stay and which work needs to be quoted.
Prepare my quote requestTalk to FenXtraFogging and care: signs to watch forYOUR LOCAL PROJECT
FenXtra serves Gatineau, the Outaouais and Ottawa. Include your municipality and the work you have in mind to help prepare a relevant request.
The insulated glass unit is the sealed glazing inside the window. When the issue is limited to this glass unit, replacing the entire window is not always necessary.
Rot, deformation or damage to the frame, water or air leaks around it, or difficulty opening the window call for a broader assessment. Replacing the glass alone does not repair defects in the frame, installation or surrounding structure. Depending on the findings, a targeted repair or full window replacement may be needed.
Condensation on the room-side or outdoor surface of the glass is different from moisture between the panes. The choice of work depends on the window’s actual condition, not its appearance alone.
THERMO RIVE-NORD · COMPONENTS MATTER
For your Thermo Rive-Nord project, glass-unit quality also comes down to its components. The technologies below offer different benefits; their inclusion and the exact glazing configuration should be confirmed in your quote.
This hybrid spacer combines polymers with low-conductivity stainless steel to limit heat transfer around the glass edge. The manufacturer’s sheet also describes its contribution to argon retention and resistance to moisture penetration. A warmer edge can help reduce condensation, but cannot eliminate it under all conditions.
This low-emissivity (Low-E) glass is designed to retain indoor heat while admitting daylight and solar warmth. Window orientation, shading and summer comfort also matter: glazing should be selected for your home rather than simply seeking the highest solar gain.
Glass-unit performance depends on the assembly: glass, coatings, pane spacing, gas and spacer. It does not, by itself, represent whole-window performance. We confirm the selected options with you before ordering.
Technical references: Technoform TGI-Spacer sheet and Guardian ClimaGuard 80/70 sheet (version 11.15). Specifications for the ordered configuration must be confirmed; no numerical energy-performance result is promised here.
FenXtra provides a 10-year warranty on the sealed glass unit and replacement labour. This labour coverage also applies when a sealed unit is replaced under warranty due to a manufacturing defect. The labour warranty is provided by FenXtra, not the manufacturer. Consult the written terms applicable to your contract for the coverage of each warranty.
This glass-replacement commitment is distinct from the general installation-correction warranty and the manufacturer warranties.
Not necessarily. Insulated glass replacement concerns the sealed glass unit. The frame can remain if its condition and compatibility allow it; an assessment determines the scope of work.
Include the number of affected glass units, their locations and the issue you notice. Photos of the whole window and the glass help prepare the assessment. Measurements, glass specifications, access and required work affect the quote.
Moisture between panes may indicate a sealed-unit seal problem. Condensation on the inside or outside surface does not necessarily have the same cause. Confirm the source before choosing the work.